5.3.3 APPX Application Design Manual

+ Chapter 1-1: Overview of Application Design
+ Chapter 1-2: Getting Started
+ Chapter 1-3: Data Dictionary
+ Chapter 1-4: Understanding Process Design
+ Chapter 1-5: Interprocess Communication
+ Chapter 1-6: Customizing Your Application
+ Chapter 1-7: The Documentation Facility
+ Chapter 1-8: Application Design Tools
+ Chapter 2-1: Data Dictionary Overview
+ Chapter 2-2: Data Dictionary Concepts
+ Chapter 2-3: Domains
+ Chapter 2-4: Files and Fields
+ Chapter 2-5: Work Fields
+ Chapter 3-1: Overview of APPX Processes
+ Chapter 3-2: Getting Started
+ Chapter 3-3: Process Definition
+ Chapter 3-4: Menu Processes
+ Chapter 3-5: Job Processes
+ Chapter 3-6: Input Processes
+ Chapter 3-7: Output Processes
+ Chapter 3-8: Update Processes
+ Chapter 3-9: Query Processes
+ Chapter 3-10: Inquiry Processes
+ Chapter 3-11: Status Processes
+ Chapter 3-12: Subroutine Processes
+ Chapter 3-13: Table Processes
+ Chapter 3-14: Automatic and Optional Children
+ Chapter 3-15: Using the Image Editor
+ Chapter 3-16: Using GUI Features of the Image Editor
+ Chapter 3-17: Using Event Points
+ Chapter 4-1: ILF Integration
+ Chapter 4-2: True/False Status Indicators
+ Chapter 4-3: Specifying Statements
+ Chapter 4-4: The ILF Editor
+ Chapter 4-5: The Appx ILF Debugger
+ Chapter 4-6: ILF Keyword Reference
- Chapter 4-7: Predefined Fields
+ Chapter 4-8: Runtime Subroutine's and Predefined Processes
+ Chapter 4-9: Appx Chart Director API

Chapter 4-7: Predefined Fields

AUTO READNEXT


 This field is used in input processes to determine whether or not APPX automatically retrieves the next record after it finishes storing the current one. It can be changed during data entry by selecting the set attributes option. In general, it is established by the designer when the input process is defined. This field can also be used in inquiry processes to control information flow.


        IF       --- MODE                       EQ     CHANGE
  T     SET      --- AUTO READNEXT              =      1
 

Default Value:

The default value is blank but can be changed to Y or N by the designer when the input process is defined, or by the user while the input process is being executed. Blank means Y in all modes except delete mode, when it means N. If AUTO READNEXT is blank when the process begins, the first record is not read from the file being maintained.

Related PDFs: EXACT KEY REQUIRED

Application Design Manual                                         "Powered by Appx Software"

755

©2006 By APPX Software, Inc. All Rights Reserved